Background: Arterial stiffness has been considered an independent predictor of cardiovascular disease in addition to the traditionally known cardiovascular risk factors. Objectives: This study aimed to investigate the associations between arterial stiffness with left ventricular mass index and carotid intima-media thickness in the hypertensives. Methods: A descriptive cross-sectional study compared a control group in 210 study subjects (105 hypertensives and 105 normotensives). Measuring left ventricular mass index by echocardiography and carotid intima-media thickness by carotid doppler ultrasonography. Pulse wave velocity was measured using the Agedio B900 device and the Agedio K520 application. The manual method was measured by the ankle-brachial index.Results: There was a statistically significant positive correlation between pulse wave velocity and age (r = 0.922, p < 0.001). The ankle-brachial index had a statistically significant positive correlation at a weak level with left ventricular mass index and carotid intima-media thickness, in which the coefficient r was equal to 0.219 (p < 0.05) and 0.250 (p < 0,001), respectively. Pulse wave velocity also had a statistically significant positive correlation at a weak level with left ventricular mass index and carotid intima-media thickness, in which the coefficient r was equal to 0.188 (p < 0.05) and 0.289 (p < 0,001), respectively. Pulse wave velocity had a multivariable linear correlation with gender, pulse, mean blood pressure, and ankle-brachial index with statistical significance; and they were written in the form of the following equation: Pulse wave velocity (R2: 41.3%) = 0.641*(Gender) – 0.027*(Pulse) + 0.043*(Mean blood pressure) + 8.378*(Ankle-brachial index) – 3.254.Conclusion: Arterial stiffness was statistically correlated with left ventricular mass index and carotid intima-media thickness in the hypertensives. Through the above research results, we suggest that the hypertensives should be combined with the evaluation of hemodynamic parameters and arterial stiffness for contributing to the diagnosis and detection of cardiovascular complications, thereby improving the quality of monitoring and treatment in hypertensive patients.
Aim: To evaluate the hemodynamic changes and side effects during endotracheal intubation with Macintosh laryngoscope and intubating laryngeal mask airway.Materials and methods: A prospective, simple randomized, comparative study on 100 patients 18 years - 60 years of age, divided into two groups: Group A comprising intubation with Macintosh laryngoscope and Group B intubation through ILMA.Results: Total intubation time (in seconds) of group A was 24.38 + 3.26 seconds and of the group, B was 42.94 + 1.24 seconds. At 2,4 and 6, a higher rise in mean heart rate was noted in group A (p < 0.05). At 2,4,6 and 8 minutes difference in mean SBP and mean DBP of the two groups was statistically significant with a p - value of < 0.05 with a significant increase of mean SBP and mean DBP in patients of group A. The difference for all complications was not significant between the two groups.Conclusion: Intubation via intubating laryngeal mask airway can be done as an alternative to direct laryngoscopy using a Macintosh blade as intubation via intubating laryngeal mask airway has shown to have lesser hemodynamic changes.
My candid opinion is that the service you render is second to none. My favourite part is the prompt response to issue, really i value that.
Abiodun Akanbi Adeogun
Thank you very much for your support and encouragement. I am truly impressed by your tolerance and support.
Thank you very much
Diaverum: PADC, Jeddah, Saudi Arabia
Nasrulla Abutaleb
"It was a pleasure to work with the editorial team of the journal on the submission of the manuscript. The team was professional, fast, and to the point".
NC A&T State University, USA
Moran Sciamama-Saghiv
Publishing an article is a long process, but working with your publication department made things go smoothly, even though the process took exactly 5 months from the time of submitting the article till the time I have favourable response, the missing part is the peer review details, which is essential in self auditing and future improvement, overall experience was excellent giving your understanding of the situation of lack of financial institution support.
Anas Diab
Your big support from researchers around the world is the best appreciation from your scientific teams. We believe that there should be no barrier in science and you make it real and this motto come true.
Arefhosseinir Rafi
"An amazing experience with the Journal of Advanced Pediatrics and Child Health. Very fast blind review with pertinent corrections and suggestions. I highly recommand both the journal and the editor."
Chaimae Khairoun
Great, We are too comfortable with the process including the peer review process and quality. But, the journal should be indexed in different databases such scopus.
Afework Edmealem
"This is my first time publishing with the journal/publisher. I am impressed at the promptness of the publishing staff and the professionalism displayed. Thank you for encouraging young researchers like me!"
Ekiti State University, Nigeria
Adebukola Ajite
Great, thank you! It was very efficient working w/ your group. Very thorough reviews (i.e., plagiarism, peer, etc.). Would certainly recommend that future authors consider working w/ your group.
David W Brett
Submission of paper was smooth, the review process was fast. I had excellent communication and on time response from the editor.
HSPI: We're glad you're here. Please click "create a new Query" if you are a new visitor to our website and need further information from us.
If you are already a member of our network and need to keep track of any developments regarding a question you have already submitted, click "take me to my Query."